You have no items in your shopping cart.
DeTech Multipliers

Detector Technology Electron Multipliers
Detector Technology, Inc. was founded in 1983 in Brookfield, Massachusetts, as a manufacturer of Continuous Dynode Electron Multipliers. In 1988, DeTech expanded its organization to include the Glass Tech division, whose core business was specialty extrusions, draws, and glass formulations for the fiber optic community. By 1992, the rapid growth of both divisions drove the need for a move to a larger, more modern facility in Sturbridge, Massachusetts. In 1996, major company reorganization split the divisions into two separate companies. This was done to better serve the customer base and provided the ability for both divisions to further expand. DeTech retained the electron multiplier product line and relocated the company to Palmer, Massachusetts, where it remains to this day.
DeTech has since expanded its capabilities into contract clean room assembly, Specialty Coatings utilizing Physical Vapor Deposition, and Custom Glass Extrusions and Draws. DeTech retains ISO 9001/2000 quality certification with a major focus on customer support and service.
DeTech multipliers are manufactured from lead glass suitably processed to yield an efficient secondary emitting layer on the inner surface. Each electron multiplier is delivered with a quality control label indicating its model number, test voltage, bias current at the test voltage and the date of shipment.
Small Horn Plug-in EM for All Agilent Mass Spectrometers

DeTech's engineers worked closely with Agilent MSD end-users to develop a replacement for the standard Agilent Plug-In element (Agilent p/n 05971-80103) which offers several performance benefits over the original element, and a much lower cost.
Vented Anode – Vent holes have been added to the anode of the detector to allow for residual gases in the detector channel and anode to be removed during pumping. Removal of these gases improves the performance and life of the detector.
Grid – When input ions enter the horn of a detector secondary electrons are created. These electrons should travel down the channel of the detector, but occasionally the secondary electrons travel out of the horn. The 10-2300 features a grid on the horn, causing all secondary electrons to travel down the detector channel, increasing the signal to noise ratio and the overall performance of the detector.
Lower Operating Voltage – The Model 10-2300 operates at a lower voltage than the standard Agilent element. The tuning voltage of Model 10-2300 is typically 1000V - 1200V. By starting detector operation at a lower voltage the overall lifetime is increased.
Increased Signal to Noise Ratio – When used in an Agilent instrument, the mechanical design changes incorporated into the 10-2300, as well as the optimized channel length, combine to increase the signal to noise ratio by approximately 25 percent.
Robust Design – The Model 10-2300 has a robust stainless steel frame to protect the glass detector from damage.
|
||||||||||||||||||||||||
Below are listed the Detector Technology multipliers for many popular ICP-MS, GC/MS and LC/MS instrument models. You can also search for other multipliers in our online catalog by instrument model or supplier part numbers. If you still can't find what you're looking for, give us a call (toll-free) at 1-800-305-0004.
GC/MS and LC/MS Multipliers
AW Part Number | Manufacturer | Instrument Model(s) |
|---|---|---|
Agilent/HP |
5985 / 5985B / 5987 / 5988 / 5988A (+/- ion) |
|
Agilent/HP |
5970 / A / B / 5992 / 5993B / 5995 (+ ion) / 5993B (+/- ion) |
|
Agilent/HP |
5930 / 5980 / A / 5981 / 5982 / 5983 / 5984 / 5985 / B / 5987 (+ ion) |
|
Agilent/HP |
5971 (old style) |
|
Agilent/HP |
5971 / 5971A / 5972A (Frame and Element) |
|
Agilent/HP |
5971 / A / 5972 / 5973 / 5975 / LC/MSD (Small Horn Plug-in) |
|
Agilent/HP |
5970 / 5971 / 5792 (Large Horn Plug-in for KM Frame) |
|
Agilent/HP |
5989 MS Engine |
|
Ampek |
Ampektron MD501 |
|
Ampek |
Ampektron MD502 |
|
Bear Instruments |
Cub Mass Spectrometer (800)/KODIAK |
|
Bruker |
Esquire |
|
Dionex |
Summit LC/MS |
|
Extrel |
Quad (All Analog Only) |
|
Extrel |
Quad (Pulse & Analog) |
|
Extrel |
QMS Series Analog / Benchmark LCMS / Questor |
|
Extrel |
MEXM / EXM System / C50 |
|
Griffin Analytical |
Minotaur Mass Spectrometer |
|
Hitachi |
RMU-6D |
|
Hitachi |
LC/MS / GC/MS Ion Trap |
|
Hitachi |
3DQ |
|
Horizon Mass Spectrometer |
Rapyd Mass Spectrometer |
|
Perkin-Elmer/Sciex |
API III LC/MS |
|
Perkin-Elmer/Sciex |
API 2000 |
|
Perkin-Elmer/Sciex |
API 100 / 200 / 300 Series / 3000 / 4000 |
|
Perkin-Elmer |
5000LS / 5500 |
|
Perkin-Elmer |
3025 / 3045 / 3067 / 3500 / 3600 / 5500 / 6000 / 6300 / 6700 / 660 / 600 |
|
Perkin-Elmer |
3010 / 10-155 / 15-155 |
|
Perkin-Elmer |
15-255 (unmounted) / 20-075 |
|
Perkin-Elmer |
AES-590 / AES-548 / 25-270 CMA / 15-255 (mounted) |
|
Perkin-Elmer |
QMass |
|
Perkin-Elmer |
Ion Trap |
|
Shimadzu |
QP5050 |
|
Shimadzu |
2010 / QP8000 / QP5000 |
|
Thermo Finnigan |
PPINICI® 4000 / 4500 / 4600 |
|
Thermo Finnigan |
PPINICI® 5100 |
|
Thermo Finnigan |
PPINICI® Incos 50 |
|
Thermo Finnigan |
1015 / 3100 / 3200 / 4000 / 4500 / 4600 (off axis) |
|
Thermo Finnigan |
1015 / 3000 / OWA® 1020 / 5100 / OWA style before 8/81 (on axis) |
Thermo Finnigan |
OWA® 1020 / 5100 / OWA style after 8/81 (base) |
Thermo Finnigan |
ITD 700 / 800 / ITS40 / Magnum |
|
Thermo Finnigan |
Polaris Q™ / GCQ™ (Full Assembly) |
|
Thermo Finnigan |
LCQ™ Deca / Duo / LC-MSQ™ / LTQ™ (Full Assembly) |
|
Thermo Finnigan |
GCQ™ / LCQ™ / SSQ® / TSQ® 7000 / PolarisQ™ / LTQ™ (Replacement Element) |
|
Thermo Finnigan |
Trace DSQ™ (Full Assembly) |
|
Thermo Finnigan |
Trace DSQ™ (Replacement Element) |
|
Varian |
Saturn I / II (unmounted) |
|
Varian |
Saturn I / II (mounted) |
|
Varian |
Saturn 2000 / 2100 / 2200 |
|
Varian |
1200 Triple Quad |
|
VG Quadrupoles |
Quad Mass Spec (Analog) / SX200 / SX300 / SQ300 |
|
VG Quadrupoles |
Quad Mass Spec (Pulse) |
|
VG Quadrupoles |
QX200 / SQ300 / SQ400 |
|
Viking Instruments |
Viking 573 |
|
VSW |
Mass Analyst Quad Type |
|
Waters |
Integrity Mass Spectrometer |
ICP-MS Multipliers
AW Part Number | Manufacturer | Instrument Model(s) |
|---|---|---|
Perkin-Elmer/Sciex |
ELAN 250 / 500 / 5000 (unmounted) |
|
Perkin-Elmer/Sciex |
ELAN 5000A (mounted) |
|
Hitachi |
ICP-MS |
|
Micromass |
PT1 / PT2 ICP-MS |
|
Seiko |
ICP-MS |
|
Shimadzu |
ICPM8500 |
|
Thermo / Finnigan |
Sola ICP |
|
Thermo Jarrell Ash (TJA) |
POEMS |
|
Thermo / VG Elemental |
PlasmaQuad / PQ1 / PQ2+ / PQ3 Standard |
Learn more about DeTech.