ATTENTION: Our Corporate Toll-Free Number (800-305-0004) Has Permanently Changed. To Reach Us Please Call (Toll-Free) 1-888-948-WEST (9378).


Assist CM

Assist CM

Assist CM

The Assist syringe-driven sample introduction system

Assists you with faster throughput
Assists you with improved accuracy
Assists you with better precision

The Assist is an automated sample introduction system for ICP-OES or ICP-MS. It consists of purpose-built programmable syringe drives with an integrated valve system. The Assist delivers the highest level of accuracy, stability and sample throughput by controlling the delivery of both sample and internal standard or diluent, eliminating the inaccuracies and pulsations caused by peristaltic pumps. The Assist provides you with:

Twice the sample throughput. The rinse time, stabilization time and the time for the sample to move from the autosampler to the nebulizer are all reduced. This reduces the time for a typical analysis by at least half.

Better precision. The sample is delivered by a precisely controlled syringe, eliminating the signal pulsation problem which occurs with the usual peristaltic pump delivery system.

Better accuracy. The internal standard is delivered by a second precision syringe drive, ensuring that the ratio of internal standard to sample is accurately maintained. The fluctuations in this ratio that occur when the internal standard is delivered by peristaltic pump are eliminated, greatly improving the analytical accuracy.

Automatic dilution. The second syringe drive can also be used to deliver a diluent, enabling accurate dilution by a factor of up to 20:1 to be carried out automatically.

Reduced carryover. The sample does not contact any peristaltic pump tubing and the sample path is totally inert. This allows for a faster rinse and reduces carryover.

Low sample and internal standard usage. The volumes required are substantially reduced, resulting in lower cost of reagents and less wastage.

Flexibility in the selection of the ratio of sample to internal standard. The syringe system allows you to use sample to internal standard ratios of up to 20:1 and still get accurate correction.

Longer life of consumables. The lower sample volume and reduced analysis time mean that you save on consumables such as torches and ICP-MS cones as well as argon.

Compatibility. The Assist software is configured to operate with almost all models of ICP-MS, ICP-OES and autosampler.

Graph of Assist v Peri Pump

Configured to suit your application

The Assist is a modular system of syringe drives and switching valves and it can be configured to suit specific applications.

Premium Package. This is the most common system and is the system described above. It incorporates two syringe drives and a Niagara switching valve. It provides for the inline delivery and mixing of the sample and internal standard or diluent.

Basic Package. This system is used when inline delivery of internal standard or diluent is not required. It incorporates a single syringe drive and a Niagara switching valve. It provides all of the benefits listed above with the exception of those relating to delivery of internal standard or diluent.

Oils Package. This system is configured specifically for the analysis of wear metals in raw (undiluted) lubricating oils. It incorporates three syringe drives and a Niagara switching valve. It takes a sample of the oil, mixes it with a diluent such as kerosene and precisely delivers the diluted oil to the ICP spectrometer. It eliminates the need for manual dilutions and increases the speed of analysis.

New Control Module

The new Assist CM is controlled by a dedicated control module rather than the instrument PC. The benefits are:

  • Faster communication, resulting in even higher sample throughput.
  • The option of running unattended without any connection to the instrument PC once the method has been loaded.
  • Simplified installation.


Assist CM Ordering Information

AW Part Number

Description

KT-1123

Assist CM Premium Package (2 syringe units)

KT-1129

Assist CM Basic Package (1 syringe unit)

KT-1132

Assist CM Oils Package (3 syringe units)

KT-1122

Assist CM Basic Package for HF with uptake syringe

KT-1131

Assist CM Premium Package for HF with uptake syringe


Brackets

A mounting bracket is required for most ICP models. Choose from the following:

AW Part Number

Description

70-803-0979

Agilent 7700/7900/8800 Series ICP-MS

70-803-1134

Varian Vista/700-ES Axial

No bracket required

Varian Vista/700-ES Radial/4100 MP-AES

No bracket required

Spectro MS

70-803-0827

All Other Instruments


Please contact us directly at 1-800-305-0004 (or +001-717-273-8400 outside the United States) for part numbers and pricing for Assist CM supplies and consumables.

7 Item(s) Show per page
View as: List  Grid  Sort by Set Descending Direction

Niagara/Assist Mounting Kit, Agilent 7800/7900 Series ICP-MS

◾︎ AW Part Number: 21-809-3982
◾︎ OEM Part Number: 21-809-3982

$866.00

Niagara/Assist Mounting Bracket, Bruker Aurora 800 Series ICP-MS

◾︎ AW Part Number: 70-803-0906
◾︎ OEM Part Number: 70-803-0906

$158.00

Assist CM Basic Package for HF with Uptake Syringe

◾︎ AW Part Number: KT-1122
◾︎ OEM Part Number: KT-1122

$17,475.00

Assist CM Premium Package (2 syringe units)

◾︎ AW Part Number: KT-1123
◾︎ OEM Part Number: KT-1123

$21,328.00

Assist CM Basic Package (1 syringe unit)

◾︎ AW Part Number: KT-1129
◾︎ OEM Part Number: KT-1129

$15,265.00

Assist CM Premium Package for HF with Uptake Syringe

◾︎ AW Part Number: KT-1131
◾︎ OEM Part Number: KT-1131

$23,381.00

Assist CM Oils Package (3 syringe units)

◾︎ AW Part Number: KT-1132
◾︎ OEM Part Number: KT-1132

$24,560.00
7 Item(s) Show per page
View as: List  Grid  Sort by Set Descending Direction