Niagara Plus

Glass Expansion | Niagara Plus

Niagara Plus CM

Niagara Plus

Halve your operating costs
Reduce your environmental footprint
Double your sample throughput

The Niagara Plus uses Flow Injection technology to reduce analysis time, environmental impact and operating cost.

  • Lower argon consumption
  • Reduced cost of consumables such as torches, cones,RF coils, pump tubing, acids, standards and chemicals
  • Lower power consumption
  • Reduced stress on RF system and lower maintenance cost
  • Less down-time for cleaning carbon from torch when analyzing organics
  • Less chemical waste to dispose of

In addition to the cost and environmental benefits, the Niagara Plus delivers a major improvement in analytical performance.

  • Twice the sample throughput for a typical analysis
  • Half the normal sample volume
  • Automatic addition of the internal standard simplifies sample preparation
  • Inert sample path reduces carryover - the sample does not contact any peristaltic pump tubing
  • Constant flow of solution to the plasma maintains plasma stability and reduces stabilization times
  • Compact design easily interfaces to almost all models of ICP-MS and ICP-OES

The Niagara Plus provides enhanced performance through unique design features.

Bubble Injector
The Niagara Plus automatically injects several air bubbles at the end of the sample plug while filling the sample loop. These air bubbles prevent boundary diffusion and do not allow the sample to mix with the carrier solution. This allows a smaller volume of sample to be used and further reduces the analysis time. Because the bubbles are injected at a programmed time they are never introduced into your nebulizer, thus avoiding any plasma disturbances.
Time In Sample (TIS) option
This feature allows you to program the time the autosampler probe sits in the sample tube, instead of waiting until the loop is filled. This prevents the sample in the uptake lines from being wasted, further reducing the amount of sample consumed. Combining the Bubble injector and TIS the Niagara Plus can save up to 55% of the sample compared to a system without these features.
Built-in internal standard tee
This low volume removable mixing tee allows the operator to tee in diluent or internal standard without significantly lengthening either the equilibration time or washout time. If you select not to tee in an internal standard or diluent, the tee can simply be removed from the valve.
Programmable Uptake Pump
The method wizard calculates the optimum pump speed for the length of the uptake tubing, including the autosampler probe and sample loop.

New Control Module

The new Niagara Plus CM is controlled by a dedicated control module rather than the instrument PC. The benefits are:

  • Faster communication, resulting in even higher sample throughput.
  • The option of running unattended without any connection to the instrument PC once the method has been loaded.
  • Simplified installation.

Niagara Plus Ordering Information

AW Part NumberDescription
KT-1118 Niagara Plus CM (requires autosampler probe)
KT-1127 Niagara Plus CM for HF with Uptake Syringe

Brackets

A mounting bracket is required for most ICP models. Choose from the following:
AW Part NumberDescription
70-803-0979 Agilent 7700/8800 Series ICP-MS
21-809-3982 Agilent 7800/7900 Series ICP-MS
70-803-0906 Bruker Aurora 800 Series ICP-MS
21-803-4065
70-803-1141
PerkinElmer Optima 2x00/4x00/5x00/7x00/8x00 DV
21-803-3690 Spectro Arcos/SpectroBlue with cyclonic spray chamber
No bracket required Agilent/Varian Vista/700-ES Radial
No bracket required Agilent 4100 MP-AES
No bracket required Spectro MS
70-803-1141 All Other Instruments

Autosampler Probes

The Niagara Plus requires a 1.0mm ID autosampler probe for correct operation. Select from the following:
AW Part NumberDescription
70-803-0793 Teflon Encapsulated Carbon Fibre Probe (Cetac ASX-520)
70-803-0816 Teflon Encapsulated Carbon Fibre Probe (PerkinElmer S-10 or AS-93+)
70-803-0853 Teflon Encapsulated Carbon Fibre Probe (Varian SPS-3 or AIM-3600)
60-703-0533 Teflon Encapsulated Carbon Fibre Probe (Agilent I-AS)
Set Descending Direction

10 Items

per page
  1. Niagara/Assist Mounting Kit, Agilent 7800/7900 Series ICP-MS
    Niagara/Assist Mounting Kit, Agilent 7800/7900 Series ICP-MS Learn More
    $866.00

    AW Part Number: 21-809-3982
    OEM Part Number(s): 21-809-3982

  2. Niagara Tray, Optima 2x00/4x00/5x00/7x00/8x00DV
    Niagara Tray, Optima 2x00/4x00/5x00/7x00/8x00DV Learn More
    $205.00

    AW Part Number: 21-809-4065
    OEM Part Number(s): 21-809-4065

  3. Niagara Plus 1.0mm Teflon Encapsulated Carbon Fibre Probe (Agilent I-AS)
    Niagara Plus 1.0mm Teflon Encapsulated Carbon Fibre Probe Learn More
    $319.00

    AW Part Number: 60-703-0533
    OEM Part Number(s): 60-703-0533

  4. Niagara Plus 1.0mm Teflon Encapsulated Carbon Fibre Probe (Cetac ASX-520)
    Niagara Plus 1.0mm Teflon Encapsulated Carbon Fibre Probe Learn More
    $286.00

    AW Part Number: 70-803-0793
    OEM Part Number(s): 70-803-0793

  5. Niagara Plus 1.0mm Teflon Encapsulated Carbon Fibre Probe (Varian SPS-3 or AIM-3600)
    Niagara Plus 1.0mm Teflon Encapsulated Carbon Fibre Probe Learn More
    $377.00

    AW Part Number: 70-803-0853
    OEM Part Number(s): 70-803-0853

  6. Niagara/Assist Mounting Bracket, Bruker Aurora 800 Series ICP-MS
    Niagara/Assist Mounting Bracket, Bruker Aurora 800 Series ICP-MS Learn More
    $158.00

    AW Part Number: 70-803-0906
    OEM Part Number(s): 70-803-0906

  7. Niagara/Assist Mounting Kit, Agilent 7700/8800 Series ICP-MS
    Niagara/Assist Mounting Kit, Agilent 7700/8800 Series ICP-MS Learn More
    $866.00

    AW Part Number: 70-803-0979
    OEM Part Number(s): 70-803-0979

  8. Adjustable Mounting Bracket for Niagara Plus CM
    Adjustable Mounting Bracket for Niagara Plus CM Learn More
    $158.00

    AW Part Number: 70-803-1141
    OEM Part Number(s): 70-803-1141

  9. Niagara Plus CM (requires autosampler probe)
    Niagara Plus CM (requires autosampler probe) Learn More
    $8,645.00

    AW Part Number: KT-1118
    OEM Part Number(s): Replaces KT-1074

  10. Niagara Plus CM for HF with Uptake Syringe
    Niagara Plus CM for HF with Uptake Syringe Learn More
    $11,196.00

    AW Part Number: KT-1127
    OEM Part Number(s): KT-1127

Set Descending Direction

10 Items

per page