Category Navigation:

You're currently on:

My Cart

You have no items in your shopping cart.

Compare Products

You have no items to compare.

 

Niagara Plus

 Niagara Plus CM

Niagara Plus

Halve your operating costs  |  Reduce your environmental footprint  |  Double your sample throughput

 

The Niagara Plus uses Flow Injection technology to reduce analysis time, environmental impact and operating cost:

  • -- Lower argon consumption
  • -- Reduced cost of consumables such as torches, cones,RF coils, pump tubing, acids, standards and chemicals
  • -- Lower power consumption
  • -- Reduced stress on RF system and lower maintenance cost
  • -- Less down-time for cleaning carbon from torch when analyzing organics
  • -- Less chemical waste to dispose of

 

 In addition to the cost and environmental benefits, the Niagara Plus delivers a major improvement in analytical performance:

  • -- Twice the sample throughput for a typical analysis
  • -- Half the normal sample volume
  • -- Automatic addition of the internal standard simplifies sample preparation
  • -- Inert sample path reduces carryover - the sample does not contact any peristaltic pump tubing
  • -- Constant flow of solution to the plasma maintains plasma stability and reduces stabilization times
  • -- Compact design easily interfaces to almost all models of ICP-MS and ICP-OES
 

The Niagara Plus provides enhanced performance through unique design features:

    • Bubble Injector: The Niagara Plus automatically injects several air bubbles at the end of the sample plug while filling the sample loop. These air bubbles prevent boundary diffusion and do not allow the sample to mix with the carrier solution. This allows a smaller volume of sample to be used and further reduces the analysis time. Because the bubbles are injected at a programmed time they are never introduced into your nebulizer, thus avoiding any plasma disturbances.

 

    • Time In Sample (TIS) option: This feature allows you to program the time the autosampler probe sits in the sample tube, instead of waiting until the loop is filled. This prevents the sample in the uptake lines from being wasted, further reducing the amount of sample consumed. Combining the Bubble injector and TIS the Niagara Plus can save up to 55% of the sample compared to a system without these features.

 

    • Built-in internal standard tee: This low volume removable mixing tee allows the operator to tee in diluent or internal standard without significantly lengthening either the equilibration time or washout time. If you select not to tee in an internal standard or diluent, the tee can simply be removed from the valve.

 

  • Programmable Uptake Pump: The method wizard calculates the optimum pump speed for the length of the uptake tubing, including the autosampler probe and sample loop.


New Control Module

The new Niagara Plus CM is controlled by a dedicated control module rather than the instrument PC. The benefits are:

  • -- Faster communication, resulting in even higher sample throughput.
  • -- The option of running unattended without any connection to the instrument PC once the method has been loaded.
  • -- Simplified installation.


Niagara Plus Ordering Information

AW Part NumberDescription
KT-1118

Niagara Plus CM (requires autosampler probe)

KT-1127

Niagara Plus CM for HF with Uptake Syringe


Brackets

A mounting bracket is required for most ICP models. Choose from the following:

AW Part NumberDescription
70-803-0979

Agilent 7700/8800 Series ICP-MS

21-809-3982

Agilent 7800/7900 Series ICP-MS

70-803-0906

Bruker Aurora 800 Series ICP-MS

21-803-4065
70-803-1141

PerkinElmer Optima 2x00/4x00/5x00/7x00/8x00 DV

21-803-3690

Spectro Arcos/SpectroBlue with cyclonic spray chamber

No bracket required

Agilent/Varian Vista/700-ES Radial

No bracket required

Agilent 4100 MP-AES

No bracket required

Spectro MS

70-803-1141

All Other Instruments

 

Autosampler Probes

The Niagara Plus requires a 1.0mm ID autosampler probe for correct operation. Select from the following:

AW Part NumberDescription
70-803-0793

Teflon Encapsulated Carbon Fibre Probe (Cetac ASX-520)

70-803-0816

Teflon Encapsulated Carbon Fibre Probe (PerkinElmer S-10 or AS-93+)

70-803-0853

Teflon Encapsulated Carbon Fibre Probe (Varian SPS-3 or AIM-3600)

60-703-0533

Teflon Encapsulated Carbon Fibre Probe (Agilent I-AS)


Please contact us directly at 1-800-305-0004 (or +001-717-273-8400 outside the United States) for part numbers and pricing for Niagara Plus supplies and consumables.

 

Items 1 to 9 of 14 total
Items 1 to 9 of 14 total Page:
  1. 1
  2. 2
  3. Next Page
Show per page
View as: Grid  List  Sort by Set Descending Direction
  1. HF Spray Chamber Mounting Bracket for Spectro ARCOS

    HF Spray Chamber Mounting Bracket for Spectro ARCOS
    $103.00

    AW Part Number: 21-809-3690
    OEM Part Number: 21-809-3690

  2. /

    Niagara/Assist Mounting Kit, Agilent 7800/7900 Series ICP-MS
    $825.00

    AW Part Number: 21-809-3982
    OEM Part Number: 21-809-3982

  3. /

    Niagara Tray, Optima 2x00/4x00/5x00/7x00/8x00DV
    $195.00

    AW Part Number: 21-809-4065
    OEM Part Number: 21-809-4065

  1. /

    Niagara Plus 1.0mm Teflon Encapsulated Carbon Fibre Probe (Agilent I-AS)
    $304.00

    AW Part Number: 60-703-0533
    OEM Part Number: 60-703-0533

  2. /

    Niagara Plus 1.0mm Teflon Encapsulated Carbon Fibre Probe (Cetac ASX-520)
    $272.00

    AW Part Number: 70-803-0793
    OEM Part Number: 70-803-0793

  3. Teflon Encapsulated Carbon Fibre Probe 1.0mm ID (suitable for PE S10 or AS93+)

    Teflon Encapsulated Carbon Fibre Probe 1.0mm ID (suitable for PE S10 or AS93+)
    $288.00

    AW Part Number: 70-803-0816
    OEM Part Number: 70-803-0816

  1. Teflon Encapsulated Carbon Fibre Probe 0.5mm ID (suitable for PE S10 or AS93+)

    Teflon Encapsulated Carbon Fibre Probe 0.5mm ID (suitable for PE S10 or AS93+)
    $298.00

    AW Part Number: 70-803-0816-SP
    OEM Part Number: 70-803-0816

  2. /

    Niagara Plus 1.0mm Teflon Encapsulated Carbon Fibre Probe (Varian SPS-3 or AIM-3600)
    $359.00

    AW Part Number: 70-803-0853
    OEM Part Number: 70-803-0853

  3. /

    Niagara/Assist Mounting Bracket, Bruker Aurora 800 Series ICP-MS
    $150.00

    AW Part Number: 70-803-0906
    OEM Part Number: 70-803-0906

Items 1 to 9 of 14 total
Items 1 to 9 of 14 total Page:
  1. 1
  2. 2
  3. Next Page
Show per page
View as: Grid  List  Sort by Set Descending Direction